The City Technology Medical replacement oxygen sensor is intended to replace the original oxygen-sensing component of an oxygen analyzer that measures oxygen concentration in breathing gas mixtures.
Device Story
Amperometric electrochemical oxygen sensors; monitor partial pressure of oxygen in breathing gas mixtures. Input: oxygen flux through solid membrane diffusion barrier. Principle: oxygen reacts at precious metal cathode to form hydroxyl ions; hydroxyl ions oxidize lead anode; electron flow through external circuit produces voltage signal proportional to oxygen partial pressure. Output: voltage signal representing oxygen concentration. Used in anesthesia, intensive care, and incubators; integrated into finished medical devices as original or replacement sensing component. Healthcare providers use output to monitor patient breathing environment; facilitates clinical decision-making regarding oxygen delivery. Benefits: ensures accurate oxygen concentration monitoring for patient safety.
Clinical Evidence
Bench testing only. Performance data provided includes measurement range, T90 response time, operating temperature/humidity ranges, cross-interference to anesthesia gases, linearity, and operating life. No clinical data presented.
Technological Characteristics
Amperometric electrochemical sensor; plastic body; precious metal cathode; lead anode; liquid electrolyte; solid membrane diffusion barrier. Operates via oxygen reduction at cathode and lead oxidation at anode. Dimensions/form factor vary by model. Standalone component for integration into medical devices. Temperature range: -20°C to +50°C; Humidity: 0-99% RH.
Indications for Use
Indicated for patients requiring monitoring of oxygen concentration in breathing gas mixtures within medical devices such as anesthesia, intensive care, and incubators.
Regulatory Classification
Identification
An oxygen gas analyzer is a device intended to measure the concentration of oxygen in respiratory gases by techniques such as mass spectrometry, polarography, thermal conductivity, or gas chromatography. This generic type of device also includes paramagnetic analyzers.
{0}------------------------------------------------
## Section 21
'JUL 1 5 2004
# 510(k) Summary
- Date: 6th April 2004 1.
- 2. Submitter/Manufacturer City Technology Limited City Technology Centre Walton Road Portsmouth Hampshire PO6 1SZ Great Britain
- 3. Contact Person Debra Wallace Quality/Environmental Systems Scientist
| 4. Contact | |
|------------|------------------------------|
| Telephone: | +44 23 9232 5511 |
| Fax: | +44 32 9238 6611 |
| E-mail: | debra.wallace@citytech.co.uk |
| Website: | www.citytech.com |
- 5. Proprietary Device Name MOX-1 Medical Oxygen Sensor MOX-2 Medical Oxygen Sensor MOX-3 Medical Oxygen Sensor MOX-4 Medical Oxygen Sensor MOX-5 Medical Oxygen Sensor MOX-6 Medical Oxygen Sensor MOX-7 Medical Oxygen Sensor MOX-8 Medical Oxygen Sensor MOX-9 Medical Oxygen Sensor MOX-10 Medical Oxygen Sensor MOX-16 Medical Oxygen Sensor
- ్. Classification Name Oxyqen Gas Analyzer (868.1720)
- 7. Common Name Medical Oxygen Sensor
- 8. Predicate Devices Ceramatec CAG-10 Sensor
{1}------------------------------------------------
- ഗ Indications for Use
Purpose: The purpose of the City Technology Medical Oxygen sensors is to be the oxygen-sensing component to monitor the concentration of oxygen in breathing gas mixtures in finished medical devices at the point of manufacture. The additional purpose of the City Technology Medical Oxygen sensors is to be a replacement for the oxygen-sensing component after the life of the sensor originally supplied in the device is exhausted, to monitor the concentration of oxygen in breathing gas mixtures in medical devices.
Function: The City Technology Medical Oxygen sensors are used in medical device products such as Anaesthesia, Intensive Care and Incubators.
Target Patient Population: The target patient population consists of those patients who require the oxygen concentration in their breathing environment to be monitored.
Environment of Use: The City Technology Medical Oxygen Sensors are used in medical devices (i.e. Anaesthesia, Intensive Care and Incubators) in patient environments whose temperatures range from -20°C to +50°C and from 0 to 99% humidity (non-condensing).
Device Claims: The City Technology Medical Oxygen Sensors consist of oxygen sensing components in medical devices that monitor the oxygen concentration in the patient's breathing environment.
Legally Marketed Predicate Device: The legally marketed predicate device is Ceramatec CAG-10 Oxygen Sensor. The predicate device was assigned 510(k) number K972992 and was declared substantially equivalent by FDA.
Safety and Effectiveness: No differences in intended use or application of the City Technology Medical Oxygen sensors or the predicate device have been identified that could affect safety or effectiveness.
- 10. Method of Operation:
These medical Oxygen sensors are based on the amperometric electrochemical measurement principle. The sensors comprise a plastic body in which are two electrodes, a precious metal cathode and a lead anode immersed in a liquid electrolyte solution, as in the schematic below.
{2}------------------------------------------------
Image /page/2/Figure/0 description: This image shows a diagram of a solid membrane diffusion barrier. The diagram includes labels for the different components of the barrier, including the solid membrane diffusion barrier, cathode, electrolyte, and anode. The diagram also shows the direction of air supply and the flow of electrons. A load resistor and voltmeter are connected to the cathode and anode.
Oxygen flows into the sensor through a solid membrane, which limits the flow and controls the output signal. Inside the sensor Oxygen reacts on the cathode to form hydroxyl ions as follows:
$$O_2 + 2H_2O + 4e^- \longrightarrow 4OH^-$$
These hydroxyl ions then oxidise the metal anode:
$2Pb + 4OH^- \longrightarrow 2PbO + 2H_2O + 4e^-$
Overall the effect is the consumption of the lead anode:
$$2Pb + O_2 \longrightarrow 2PbO$$
The electrons consumed at the cathode are supplied from the anode via the external circuit where a resistor is placed so that the voltage produced may be monitored. This voltage signal then constitutes a measure of the flux of Oxygen into the sensor and hence the partial pressure of Oxygen in front of the membrane.
The life of the sensor is governed by the mass of lead and the rate of consumption i.e. by the oxygen partial pressure; hence lifetimes are quoted as % Oxygen hours.
Accuracy is governed largely by the variation in diffusion rate of Oxygen through the solid membrane, which is a function of temperature and the presence of interfering gases that may absorb onto the membrane.
- 11. Intended Use
These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia, critical care, incubators and general oxygen monitors.
{3}------------------------------------------------
#### Predicate Device Comparison 12.
| | Predicate<br>Device<br>CAG-10 | CTL MOX-1,<br>2, 3, 4, 7, 8<br>& 10 | CTL MOX-5,<br>6 and 9 | CTL<br>MOX-5 | CTL MOX-<br>16 |
|------------------------------------------------------------|-------------------------------|-------------------------------------|-----------------------|--------------------------|-----------------------|
| Measurement<br>Range | 0-100% | 0-1500<br>mBar | 0-1500<br>mBar | 0-1500<br>mBar | 0-1500<br>mBar |
| T90 | <15s | <15s | <15s | <20s | <15s |
| Operating<br>Temperature<br>Range | 10-40°C | -20°C -<br>+50°C | -20°C -<br>+50°C | -20°C -<br>+50°C | -20°C -<br>+50°C |
| Operating<br>Humidity<br>Range | 10-95% RH | 0-99%RH | 0-99% RH | 0-99% RH | 0-99% RH |
| Cross-<br>Interference<br>to<br>Anaesthesia<br>Agent Gases | <1% | <±2% | <±2% | <±2% | <±2% |
| Linearity | ±2% | R2>0.9999 | R2>0.9999 | R2>0.9999 | R2>0.9999 |
| Operating Life | >900,000<br>%O2 Hours | 1,600,000 %<br>O2 Hours | >900,000<br>%O2 Hours | >900,000<br>%O2<br>Hours | >650,000<br>%O2 Hours |
The MOX-1, 2, 3, 4, 7, 8 and 10 Sensors differ only in body shape and electrical interface type, but are otherwise identical and can be considered equivalent.
The MOX-5, 6 and 9 Sensors differ only in body shape and electrical interface type, but are otherwise identical and can be considered equivalent.
The MOX-16 sensor is a dual cathode version of the other Medical Oxygen Sensors. It also has a different body shape and electrical interface, but otherwise it is identical and can therefore be considered equivalent.
- 13. Conclusion
City Technology's Medical Oxyqen Sensors are substantially equivalent to the predicate devices listed. Medical Oxygen Sensors are safe and effective for their intended use.
{4}------------------------------------------------
Image /page/4/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS). The seal features a stylized eagle with three stripes representing the three levels of government: federal, state, and local. The eagle is encircled by the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" in a circular arrangement.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
JUL 1 5 2004
City Technology Limited C/O Jeff D. Rongero Underwriters Laboratories, Incorporated 12 Laboratory Drive Research Triangle, NC 27709
Re: K041773
Trade/Device Name: Medical Oxygen Sensors, MOX -1, 2, 3, 4, 5, 6, 7, 8, 9, 10, and 16 Regulation Number: 868.1720 Regulation Name: Oxygen Gas Analyzer Regulatory Class: II Product Code: CCL Dated: June 25, 2004 Received: July 1, 2004
Dear Mr. Rongero:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition. FDA may publish further announcements concerning your device in the Federal Register.
{5}------------------------------------------------
### Page 2 - Mr. Rongero
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4646. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html.
Sincerely yours,
Kein Muluy
Chiu Lin, Ph.D.
Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{6}------------------------------------------------
### Indications for Use
K041773 510(k) Number (if known):
Device Name:
MOX-1,2,3,4,5,6,7,8,9,10 and 16 Medical Oxygen Sensors
Indications For Use: The City Technology Medical replacement oxygen sensor is intended to replace the original oxygen-sensing component of an oxygen analyzer that measures oxygen concentration in breathing gas mixtures.
Prescription Use X (Per 21CFR 801.109) OR
Over-The-Counter Use __ www
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Quy Syuun
Page I of 1
(Division Sign-Off) (Division Sign-Oil)
Division of Anesthesiology, General Hospital, Division Control, Dental Devices
FD 1030 Issue 1
510(k) Number
(Posted November 13, 2003)
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.