The SURFIX® Knee Osteotomy System is intended for open and closed wedge osteotomies of the proximal tibia and the distal femur, treatment of bone and joint deformities, and malalignment caused by injury or disease such as osteoarthritis.
Device Story
SURFIX Knee Osteotomy System comprises stainless steel plates and titanium alloy or stainless steel screws/lock screws. System provides locking mechanism between threaded plate sockets and screws, creating single implant/screw unit fixed into bone. Used by surgeons for proximal tibia and distal femoral osteotomies to treat bone/joint deformities and malalignment (e.g., osteoarthritis). Device stabilizes bone segments during healing; benefits patient by restoring alignment and reducing joint pain.
Clinical Evidence
Bench testing only. Dynamic fatigue strength testing and static bending/twisting strength tests performed to evaluate mechanical resistance and behavior compared to common bone plates.
Technological Characteristics
System consists of stainless steel plates and titanium alloy or stainless steel screws (cancellous 6.5mm, cortical 4.5mm). Features locking mechanism between threaded plate sockets and screws. Mechanical fixation via single implant/screw unit. No software or electronic components.
Indications for Use
Indicated for knee osteotomies including high tibial osteotomy and femoral osteotomy in cases of osteoarthritis of the medial tibiofemoral compartment with genu varum and lateral gonarthrosis on genu valgum. Specific applications include fixation of opening/closing wedge high tibial osteotomy, fixation of medial/lateral tibial plateau fractures, and distal femoral varus osteotomy.
Regulatory Classification
Identification
Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.
{0}------------------------------------------------
K041601
1 OF 3
# AUG 2 7 2004
### SUMMARY OF SAFETY AND EFFECTIVENESS 3.
#### SPONSOR IDENTIFICATION A.
SURFIX TECHNOLOGIES SA Parc Tertiaire des Grésillières 7 avenue Jules Verne 44 230 SAINT SEBASTIEN SUR LOIRE - FRANCE
Tel.: (33) 2 40 80 72 38 Fax: (33) 2 40 80 72 39
#### ESTABLISHMENT REGISTRATION NUMBER B.
Pending
#### OFFICIAL CONTACT PERSON C.
Norman F. Estrin, Ph. D., RAC President Estrin Consulting Group, Inc. 9109 Copenhaver Drive Potomac , MD 20854
Tel .: (301) 279 -2899 Fax: (301) 294-0126 estrin @yourFDAconsultant.com
## DATE OF PREPARATION OF THIS SUMMARY: March 24, 2004
#### D. PROPRIETARY (TRADE) NAME
SURFIX® Knee Osteotomy System
#### E. COMMON NAME
SURFIX® pre moulded plate for opening wedge high tibial osteotomy right and left sides
SURFIX® pre moulded plate for closing wedge high tibial osteotomy right and left sides
SURFIX® reinforced and pre moulded plate for closing wedge high tibial osteotomy right and left sides
SURFIX® distal femoral varus osteotomy plate
#### DEVICE CLASSIFICATION NAME F.
PLATE, FIXATION, BONE (21 CFR PAR. 888.3030)
{1}------------------------------------------------
K041601
20F3
#### PROPOSED REGULATORY CLASS G.
Class II
#### DEVICE PRODUCT CODE H.
87 HRS
#### PANEL CODE l.
87 OR Orthopedic
#### DEVICE DESCRIPTION J.
The SURFIX® Knee Osteotomy System consists of seven different Stainless Steel plates with a locking system between the threaded sockets of the plates and the lock screws. There are six plates for the proximal tibia and one plate for the distal femur. Their fixation is provided by Titanium alloy or Stainless Steel SURFIX® screws and lock screws available in two versions: cancellous bone screws diameter 6.5 mm and cortical bone screws diameter 4.5 mm. The SURFIX® system fixation creates a single implant/screw unit fixed into the bone thanks the lock screw.
| INTENDED USE: | The SURFIX® Knee Osteotomy System is intended<br>for open and closed wedge osteotomies of the proximal<br>tibia and the distal femur, treatment of bone and joint<br>deformities, and malalignment caused by injury or<br>disease such as osteoarthritis. |
|-------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| INDICATIONS FOR<br>USE: | The SURFIX® Knee Osteotomy System is indicated<br>for knee osteotomies including high tibial osteotomy<br>and femoral osteotomy in the cases of osteoarthritis of<br>the medial tibiofemoral compartment with genu varum<br>and lateral gonarthrosis on genu valgum. Examples<br>include: |
| | - Fixation of opening wedge high tibial osteotomy,<br>- Fixation of fracture of the medial tibial plateau,<br>- Osteoarthritis of the medial tibiofemoral<br>compartment with genu varum,<br>- Fixation of closing wedge high tibial osteotomy,<br>- Fixation of fracture of the lateral tibial plateau,<br>- Distal femoral varus osteotomy,<br>- Lateral gonarthrosis on genu valgum. |
| PREDICATE DEVICE: | The SURFIX® Knee Osteotomy System is<br>substantially equivalent to the Synthes TomoFix™<br>Osteotomy System (K023941) and the Arthrex<br>Modified Osteotomy System (K014155). |
{2}------------------------------------------------
### PARISON OF OLOGICA ERISTICS:
The three systems are recommended for fixation of osteotomies, including high tibial osteotomy and femoral osteotomy.
For the Arthrex Modified Osteotomy System, plates and screws are made of Stainless Steel. For the Synthes TomoFix™ Osteotomy System, plates and screws are made of Titanium alloy. The SURFIX® Knee Osteotomy System provides plates made of Stainless Steel and, screws and lock screws made of Titanium alloy or Stainless Steel.
The three systems are fixed with screws.
### UMMARY OF STODIES:
Dynamic tests determining fatigue strength indicate the good mechanical resistance of the SURFIX® Knee Osteotomy System.
Static tests determining bending strength in flexion and twisting of bone plates indicate the similar mechanical behavior of the SURFIX® Osteosynthesis System with a common plate.
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized symbol that resembles three human profiles facing to the right, with flowing lines suggesting movement or connection.
AUG 27 2004
Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
SURFIX Technologies S.A. C/o Norman F. Estrin, Ph.D., RAC President Estrin Consulting Group, Inc. 9109 Copenhaver Drive Potomac, Maryland 20854
Re: K041601
Trade/Device Name: SURFIX® Knee Osteotomy System Regulation Numbers: 21 CFR 888.3030 Regulation Name: Single/multiple component metallic bone fixation appliances and accessories Regulatory Class: II Product Code: HRS Dated: March 24, 2004 Received: June 14, 2004
Dear Dr. Estrin:
We have reviewed your Section 510(k) premarket notification of intent to market the device we nave teviewed your bected by the device is substantially equivalent (for the indications ferenced above and haves re and in marketed predicate devices marketed in interstate for use stated in the encreations of the enactment date of the Medical Device Amendments, or to conimered pror to rial) 2012-12-12 in accordance with the provisions of the Federal Food, Drug, devices that have been rocksonied require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The r ou may, mererors, mains of the Act include requirements for annual registration, listing of general voltario profice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it If your device is olaborned (600 w or of ols. Existing major regulations affecting your device can may be subject to basil additions, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean r lease be act not a a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must
{4}------------------------------------------------
# Page 2 -- Norman Estrin, Ph.D., RAC
comply with all the Act's requirements, including, but not limited to: registration and listing (21 comply with all the Act s requirements, merading practice requirements as set CFR Part 807), labeling (21 CFR Part 800), government 820); and if applicable, the electronic
forth in the quality systems (QS) regulation (21 CFR Part 81 CFR 1000 1050 forth in the quality systems (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) I his letter will anow you to begin marketing your aviral equivalence of your device to a legally premarket nother in TDA miaing of castion for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Patting spitiled If you desire specific advice for your act 100 %. 659. Also, please note the regulation entitled, p contact the Office of Comphalled at (501) 37 - 17 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 " Wissolalling by reference to promantee nobilities under the Act from the Division of Small other general informational and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
Sincerely yours,
Mark N. Milliman
Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
Page 1 of 1
K041601 510 (k) Number (if known) : SURFIX Knee Osteotomy Device Name :
Indications for Use :
The SURFIX® Knee Osteotomy System is indicated for knee osteotomies including high tibial osteotomy and femoral osteotomy in the cases of osteoarthritis of the medial tibiofemoral compartment with genu varum and lateral gonarthrosis on genu valgum. Examples Include:
- Fixation of opening wedge high tibial osteotomy, .
- Fixation of fracture of the medial tibial plateau, .
- Osteoarthritis of the medial tibiofemoral compartment with genu . varum,
- Fixation of closing wedge high tibial osteotomy, .
- Fixation of fracture of the lateral tibial plateau, ●
- Distal femoral varus osteotomy,
- Lateral gonarthrosis on genu valgum.
OR
Prescription Use
(Per 21 CFR 801.109)
Over -the-counter Use
(Optional format 1-2-96)
(PLEASE DO NOT WRITE BELOW THIS LINE -CONTINUE ON ANOTHER PAGE IF NEFDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Mark A. Millhuser
(Division Sign-Off) Division of General, Restorative, and Neurological Devices
K04160
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.