Intended to provide CPAP for use in hospitals to treat newborns and infants less than 5kg body weight with RDS or which are recovering from RDS (Respiratory Distress Syndrome). May or may not include humidification capabilities.
Device Story
Guardian Neonate CPAP/Humidification System provides non-invasive respiratory support for neonates/infants <5kg. Device mixes air and oxygen (21-100%) and delivers flow (1-20 L/min) at CPAP pressures (2-10 cm H2O). Humidification provided via Vapotherm microporous membrane. System includes patient circuits, accessories, and interfaces for single-patient use. Operated by hospital staff; monitors circuit pressure, FiO2, and gas temperature (33-41°C) via integrated displays. Alarms alert clinicians to high/low pressure, FiO2, or temperature deviations. Pressure relief valve set at 18 cm H2O ensures safety. Device supports patient recovery from RDS by maintaining airway patency through continuous positive airway pressure.
Clinical Evidence
No clinical data provided; substantial equivalence is supported by bench testing and technical performance specifications.
Technological Characteristics
Non-invasive CPAP system; provides 2-10 cm H2O pressure; 21-100% O2 concentration; 1-20 L/min flow. Humidification via Vapotherm microporous membrane. Gas temperature range 33-41°C. Features pressure relief valve (18 cm H2O), AC/battery power, and visual bar graph/window displays for pressure, O2, and temperature. Alarms for pressure, FiO2, and temperature. Single-patient use circuits.
Indications for Use
Indicated for newborns and infants < 5kg body weight with Respiratory Distress Syndrome (RDS) or recovering from RDS, requiring non-invasive CPAP respiratory support in a hospital setting.
Regulatory Classification
Identification
A noncontinuous ventilator (intermittent positive pressure breathing-IPPB) is a device intended to deliver intermittently an aerosol to a patient's lungs or to assist a patient's breathing.
{0}------------------------------------------------
K040862
## Summary of Safety and Effectiveness
## Non-Confidential Summary of Safety and Effectiveness
Page 1 of 2 29 June 2004
| Official Contact: | John O'Dea, Ph.D. - General Manager | |
|----------------------------|--------------------------------------------------------------------|--|
| Proprietary or Trade Name: | Guardian Neonatal CPAP / Humidification System | |
| Common/Usual Name: | CPAP system | |
| Classification Name: | Ventilator, non-continuous (Respirator) | |
| Predicate Devices: | EME - Infant Flow systems - K011516<br>Vapotherm - 2000I - K000401 | |
# Device Description
The Guardian Neonate CPAP / Humidification systems is non-invasive respiratory support device for neonatal patients
| Intended Use and Environments | |
|-------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Intended Use -- | Intended to provide CPAP for use in hospitals to<br>treat newborns and infants less than 5kg body weight with<br>RDS or which are recovering from RDS (Respiratory<br>Distress Syndrome). May or may not include humidification<br>capabilities. |
| Environment of Use -- | Hospital |
{1}------------------------------------------------
### Non-Confidential Summary of Safety and Effectiveness Page 2 of 2 29-Jun-04
General Technical Characteristics
| Attribute | Guardian CPAP System |
|-------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------|
| Intended to provide CPAP for neonates and infants < 5kg body weight with RDS or recovering from RDS (Respiratory Distress Syndrome) | Yes |
| Humidification of gases | Yes |
| Environment of Use - Hospital | Yes |
| Single patient use circuits and accessories including patient interfaces | Yes |
| Design Features and Specifications | |
| CPAP – Range of pressure | 2 to 10 cm H2O |
| Air / Oxygen mixture | Yes |
| % O2 range | 21 – 100% |
| Range of Flow delivered | 1 to 15 Lpm (Flow Mode)<br>1 to 20 L/min (CPAP Mode) |
| Humidification method | Vapotherm microporous membrane |
| Range of temperature of gas delivered | 33 to 41 °C |
| Measured Data | |
| Circuit Pressure (bar graph display) Range | 0-12 cm H2O |
| % O2 (window display) - Range | 21-100% |
| Gas temperature - Range | 10-50 °C |
| Flow (bar graph) | Indicator |
| Power | AC and Battery |
| Pressure Relief Valve | 18 cmH2O |
| Alarms | High and Low Pressure<br>High and Low FIO2<br>High and Low Temperature |
| Supply Gases Failure | Air and Oxygen |
## Differences between Other Legally Marketed Predicate Devices
The data within the submission demonstrates that the proposed device when compared to the predicate device is safe and effective and is substantially equivalent.
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image shows the seal of the Department of Health & Human Services - USA. The seal is circular and contains the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. In the center of the seal is an abstract symbol that resembles an eagle or bird-like figure. The symbol is composed of several curved lines and shapes.
#### Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
JUN 3 0 2004
Mr. John O'Dea General Manager Caradyne, Limited Parkmore Business Centre Parkmore West Galway. IRELAND
Re: K040862
Trade/Device Name: Guardian Neonate CPAP / Humidification System Regulation Number: 21 CFR 868.5895 Regulation Name: Continuous Ventilator Regulatory Class: II Product Code: CBK Dated: June 11, 2004 Received: June 14, 2004
Dear Mr. O'Dea:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{3}------------------------------------------------
Page 2 - Mr. O'Dea
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4646. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely vours.
Chi-Lien, Ph.D.
Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
| Indications for Use<br>L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L, L,<br>1 |
|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
K040862 510(k) Number:
Guardian Neonate CPAP / Humidification system Device Name:
Indications for Use:
Intended to provide CPAP for use in hospitals to treat newborns and infants less than 5kg Intended to provide of provish are recovering from RDS. (Respiratory Distress Syndrome) May or may not include humidification capabilities
or Over-the-counter use __ Prescription Use XX (Per CFR 801.109)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Quu Suliom
(Division Sigh-Off) (Division Sigh-Off))
Division of Anesthesiology, General Hospital, Division of Anesthoolonsis.
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
510(k) Number: K040862
್
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.