K040757 · Sic Invent AG · DZE · Apr 13, 2005 · Dental
Device Facts
Record ID
K040757
Device Name
SIC PRO
Applicant
Sic Invent AG
Product Code
DZE · Dental
Decision Date
Apr 13, 2005
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.3640
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The SIC pro System Dental Implant is a root form endosseous dental implant system that is indicated to be implanted in the upper and/or lower jaw arches. The implants may be used in combination with various SIC pro System Abutments for single or multiple unit prosthetic attachment to restore a patient's chewing function. Patient's must be applicable for dental treatment with endosseous implants. In cases where the ridge is too narrow to recieve a 4.2mm or 5.3mm diameter implant, the 3.3mm implant can be used. Under such conditions, we highly recommend the placement of additional fixtures to share the occlusal load of the prosthetic restoration. The SIC pro System Abutment is intended to be placed into the SIC pro System Implant to provide a safe and effective fit of screw retained and/or cementable crowns and bridges.
Device Story
SIC pro System consists of root-form endosseous dental implants and associated abutments; used by dentists/oral surgeons to restore patient chewing function. Implants are solid screw-type, grade 4 titanium, acid-etched surface for osseointegration; available in various diameters/lengths. Abutments are titanium grade 5, 316L steel, or zirconium oxide. Implants feature hexagon drill hole and screw thread for anti-rotational connection to abutments. Implants supplied sterile (gamma-radiation); abutments supplied non-sterile, requiring user steam sterilization (136°C, 15 min). Clinical benefit: provides stable foundation for screw-retained or cementable crowns and bridges.
Clinical Evidence
Bench testing only. No clinical data provided.
Technological Characteristics
Materials: Grade 4 titanium (ASTM F 67) for implants; Grade 5 titanium, 316L steel, and zirconium oxide for abutments. Design: Root-form, solid screw, acid-etched surface. Connection: Hexagon drill hole/socket for anti-rotational fit. Sterilization: Gamma-radiation (implants); steam autoclave (abutments).
Indications for Use
Indicated for patients requiring dental restoration via endosseous implants in upper or lower jaw arches. Used for single or multiple unit prosthetic attachment to restore chewing function. Contraindicated for patients not applicable for dental treatment with endosseous implants.
Regulatory Classification
Identification
An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.
Special Controls
*Classification.* (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2)
*Classification.* Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use;
(ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads;
(iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system;
(iv) The device must be demonstrated to be biocompatible;
(v) Sterility testing must demonstrate the sterility of the device;
(vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment;
(vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians;
(viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and
(ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.
{0}------------------------------------------------
K04075-7
APR 1 3 2005
Implants from Implantologists
Image /page/0/Picture/3 description: The image shows a logo with the letters "SIC" inside of a circle. To the upper right of the circle is the registered trademark symbol. The letters are in a sans-serif font and are black. The circle is also black.
# K040757
# SIC pro Dental Implant System
# 510(K) SUMMARY OF SAFETY AND EFFECTIVENESS
DATE: 2005-03-07
#### Establishment:
SIC invent AG Birmannsgasse 3 Basel, SWITZERLAND 4055 Registration Number: 3004443656
#### Official Correspondent:
Georg Schilli (CEO & Chairman) SIC invent AG Birmannsgasse 3 Basel, SWITZERLAND 4055 Phone: +41-61-2613966 Fax: +41-61-2613968 Email: georg.Schilli@sic-invent.com
#### Owner/Operator:
SIC invent AG Birmannsgasse 3 Basel, SWITZERLAND 4055 Owner/Operator Number: 9060857
### US Agent:
MEDAGENT, Inc. Christa Heitmann-Franke One Park Ave, Suite #5G Hampton, 03842 NH Phone: 603-758-1029 Fax: 603-758-1029 Email: mail@sic-invent.com
#### Description of the Device 1.
### 1.1. Device Name & Classification
| Common/Generic Device Name: | ENDOSSEOUS DENTAL IMPLANT, COMPONENTS & AC-<br>CESSORIES |
|-----------------------------|----------------------------------------------------------|
| Classification Name: | IMPLANT, ENDOSSEOUS, ROOT-FORM |
| Trade Name: | SIC pro System, Dental Implants & Accessories |
| Regulation Number: | 872.3640 |
### 1.2. Description of SIC pro System Implants
SIC pro System solid screw dental implants are root-form endosseous dental implant devices ono of of grade 4 titanium according ASTM F 67. The implants are available in three different diameters (ø3.3 mm, ø4.2 mm, ø5.3 mm) and various length from 7.5 mm up to 16 mm. All ø3.3 mm diameter implants are cylindrical as well as the implants in diameter ø4.2 mm and ø5.3 mm in
{1}------------------------------------------------
#### Implants from Implantologists
Image /page/1/Picture/1 description: The image shows a logo with the letters "SIC" inside of a circle. There is a registered trademark symbol in the upper right corner of the circle. The letters are in a simple, sans-serif font. The logo is black and white.
length of 7.5mm. All other implants in diameter ø4.2 mm and ø5.3 mm are partly tapered. The rength of 7.3mm. All other implants in acid etched for faster osseointegration and secondary stability.
The face side of the implant has a hexagon drill hole and a standard screw thread to ensure a The face side of the implant not a noxagon and the implant. Throughout the implant. Throughout the different diameters the hexagon drill hole has identical measurements.
SIC pro System Implants are delivered single packed in combination with a implant cover screw and supplied in sterile condition (sterilized by gamma-radiation).
## 1.3. Description of SIC pro System Abutments & Accessories
SIC pro System Abutments & Accessories are various in shape, length and diameters and made out of three different materials (titanium grade 5, implant steel 316L, zirconium oxide). Through a hexagon socket and a vertical drill hole, the abutments can be connected with the implant secure and anti-rotational.
SIC pro System Abutments & Accessories are supplied single packed in non-sterile condition. These parts of the system are intended to be sterilized by the user by and have been validated by These parts of the system are intoneed steam (autoclave) sterilization process (15 min., 136°C, 3 bar).
#### Predicate Devices 2.
- Straumann AG, ITI Dental Implant System®, K033984; u
- FRIADENT GmbH, ANKYLOS® Dental Implant System, K040946;
- Nobel Biocare USA Inc., Nobel Biocare Endosseous Iplants, K041661; .
- Straumann AG, 1.5mm synOcta Abutment, K022859; .
- Friadent GmbH, XIVE® TG Abutment, K032302. I
#### Indication for Use 3.
The SIC pro System Dental Implant is a root form endosseous dental implant system that is indicated to be implanted in the upper and/or lower jaw arches. The implants may be used in combination with various SIC pro System Abutments for single or multiple unit prosthetic attachment to restore a patient's chewing function.
Patient's must be applicable for dental treatment with endosseous implants.
In cases where the ridge is too narrow to recieve a 4.2mm or 5.3mm diameter implant, the 3.3mm implant can be used. Under such conditions, we highly recommend the placement of additional fixtures to share the occlusal load of the prosthetic restoration.
The SIC pro System Abutment is intended to be placed into the SIC pro System Implant to provide a safe and effective fit of screw retained and/or cementable crowns and bridges.
#### Conclusions 4.
Based on the available 510(k) summaries and 510(k) statements (21 CFR 807) and the informa-Dased on the uvaliders over that the SIC pro System Dental Implants, Abutments and Action provided from we squivalent to the existing legally marketed devices under Federal Food, Drug and Cosmetic Act.
{2}------------------------------------------------
## DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/2/Picture/1 description: The image shows the logo for the Department of Health & Human Services (HHS). The logo features a stylized caduceus, a symbol often associated with medicine and healthcare, consisting of a staff with two snakes coiled around it and wings at the top. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" is arranged in a circular fashion around the caduceus.
Public Health Service
APR 1 3 2005
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Mr. Georg Schilli Official Correspondent SIC Invent AG Birmannsgasse 3 Basel, SWITZERLAND 4055
Re: K040757
Trade/Device Name: SIC pro System Regulation Number: 872.3640 Regulation Name: Endosseous Implant Regulatory Class: II Product Code: DZE Dated: April 7, 2005 Received: April 11, 2005
Dear Mr. Schilli:
We have reviewed your Section 510(k) premarket notification of intent to market the device We have reviewed your securer researce is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device micrstate conments, or to devices that have been reclassified in accordance with the provisions of Amendinents, of to devroes mar na nat (Act) that do not require approval of a premarket the rederal I vou, Drug, and Commay, therefore, market the device, subject to the general approval approvisions of the Act. The general controls provisions of the Act include controls provisions of the engistration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III II your device is classinod (See as 10) in a controls. Existing major regulations affecting (FMA), it may oc subject to sach adataf Federal Regulations, Title 21, Parts 800 to 898. In your device can be found in the Oout nouncements concerning your device in the Eederal Register.
{3}------------------------------------------------
### Page 2 - Mr. Georg
Please be advised that FDA's issuance of a substantial equivalence determination does not Please be advisod that 1 DTS issualites or abat your device complies with other requirements mean that IDA has made a decement regulations administered by other Federal agencies. Of the Act of ally I oderal backed in requirements, including, but not limited to: registration Y ou must configry with an the Pisoeling (21 CFR Part 801); good manufacturing practice allo listing (21 OF R Part 807), abality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) I mis letter will anow you to ough finding of substantial equivalence of your device to a premarket notification. The PDF results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), If you desire specific at no not your at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the may obtain other generational and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
Clus
Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
# Indications for Use
510(k) Number (if known): K040757
Device Name: SIC pro System
Indications for Use:
The SIC pro System Dental Implant is a root form endosseous dental implant system that is indicated to be implanted in the upper and/or lower jaw arches. The implants may be used in combination with various SIC pro System Abutments for single or multiple unit prosthetic attachment to restore a patient's chewing function.
Patient's must be applicable for dental treatment with endosseous implants. In cases where the ridge is too narrow to recieve a 4.2mm or 5.3mm diameter implant, the 3.3mm implant can be used. Under such conditions, we highly recommend the placement of additional fixtures to share the occlusal load of the prosthetic restoration. The SIC pro System Abutment is intended to be placed into the SIC pro System Implant to provide a safe and effective fit of screw retained and/or cementable crowns and bridges.
YES___________________________________________________________________________________________________________________________________________________________________________ Prescription Use (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use __NO_ (21 SFR 801 Subpart C)
PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Sipa Rinsur
: .. IS on Sion-Off) uclaion of Anesthesiology, General Hospital Intection Control. Dental Devices 100k) Number
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.