UB 140

K033827 · Rivertrail Mobility · ITI · Dec 18, 2003 · Physical Medicine

Device Facts

Record IDK033827
Device NameUB 140
ApplicantRivertrail Mobility
Product CodeITI · Physical Medicine
Decision DateDec 18, 2003
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 890.3860
Device ClassClass 2
AttributesTherapeutic, 3rd-Party Reviewed

Indications for Use

The intended function and use is to provide mobility to persons limited to a sitting position that have the capability of operating a powered wheelchair.

Device Story

UB 114 is a powered wheelchair providing mobility to users with limited sitting capacity. Device comprises a powerbase (motors, batteries, charger, wheels) and a body support system (adjustable seating, joystick controller). Inputs: user manual operation via joystick. Transformation: joystick signals control two motor-gearbox combinations powering 14-inch front drive wheels; 24-volt DC power from gel-cell batteries. Outputs: physical movement of the wheelchair. Used in various environments by the patient. Features include rear articulating casters for balance, front stabilizer wheels to prevent tipping, and a Uni-Body aluminum alloy frame enclosing electrical components. Healthcare providers use the device to restore mobility; patient benefits from independent navigation and adjustable seating comfort.

Clinical Evidence

Bench testing only. Testing conducted per FDA guidance for mechanical and powered wheelchairs, including ANSI/RESNA WC/02 1991 (Static Stability, Dynamic Stability) and ANSI/RESNA WC/Vol. 2-1998 (EMC Testing).

Technological Characteristics

Aluminum alloy Uni-Body frame; 24V DC power via gel-cell batteries; dual motor-gearbox drive system; 14-inch front drive wheels; joystick-based controller; onboard battery charger; adjustable seating with tilt-back and lumbar support. Standards: ANSI/RESNA WC/02 1991, ANSI/RESNA WC/Vol. 2-1998.

Indications for Use

Indicated for persons limited to a sitting position who possess the capability to operate a powered wheelchair.

Regulatory Classification

Identification

A powered wheelchair is a battery-operated device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/2 description: The image shows a series of handwritten characters and numbers. The first part of the sequence appears to be 'KO33827'. Below this sequence, there is another line that reads '1 or 2'. The handwriting is somewhat stylized, with some characters having distinct loops and strokes. #### 510K Summary of Safety and Effectiveness 7.1 River Trail, Inc 369 FACTORY RD. Clinton , AR 72031 Ph (501) 745-6790 Fax (501) 745-6792 Manufacture: RiverTrail Mobility 369 Factory Rd. Clinton AR 72031 Voice: 1-501-745-6790 Fax: 1-501-745-6792 Date Prepared: October 02, 2003 FDA Registration number: None at this time. Contact Person: Clark Stancil Proprietary Name of New Device: UB 114 Generic Name of Device: Powered Wheelchair Classification of the Predicate Device: Class II, ITI 890.3860 Powered Wheelchair # K945936 Jazzy Proposed regulatory code from 21CFR890.3860: Class II 890.3860 Powered Wheelchair Panel Code for the Device: 89 Physical Medicine ITI #### Intended Use The intended function and use is to provide mobility to persons limited to a sitting position that have the capability of operating a powered wheelchair. #### Description of Device The Power Wheelchair consists of two basic sections to complete the finished component. 1) The powerbase containing motors, batteries, charger and wheels. 2) The body support system containing contoured adjustable seating and the joystick dual integrated controller. The UB 114 consists of two motor gearbox combinations that power two 14" diameter front drive wheels. The electrical power source comes from two gel-cell type batteries placed in electrical series for a 24-volt direct current application. Motor control and the battery recharging monitoring is from a Joystick Controller. As part of the electrical system the UB114 employs a battery charger which is mounted "onboard" the power base. Rear weight, rear balance and rear force load distribution is achieved by two vertical articulating caster wheels. These wheels are mounted directly to the power base. The caster wheels rotate a full 360-degree movement about the vertical mount axis while supporting the rear force load. {1}------------------------------------------------ K033827 2 OF 2 Constructed fully from Aluminum Alloy this Power Chair is the first in its class to have a Uni-Body style frame. All key electrical components, batteries, motor gearboxes, battery charger and wiring are enclosed within the Uni-body frame. The exterior is finished in a high performance and durable epoxy type paint. #### Technological Characteristics/Comparison Summary The UB114 is substantially equivalent to the predicate device in as they are both Joystick controlled. Utilize onboard battery charger and batteries. They are both midwheel drive power chairs with rear casters and front anti-tip wheels. # Non-Clinical tests performed for determination of Substantial Equivalence Tests listed in the Guidance Document for the Preparation of Premarket Notification 510K Applications for Mechanical and Powered Wheelchairs and Motorized Three Wheeled Vehicles. ANSI/RESNA WC/02 1991 Wheelchair Standard for Static Stability ANSI/RESNA WC/02 1991 Wheelchair Standard for Dynamic Stability ANSI/RESNA WC/Vol. 2-1998 Wheelchair Standard for EMC Testing ## Conclusions of Non-Clinical Tests The UB114 has the same intended use and similar technological characteristics as the Predicate Device. The non-clinical testing and predicate comparisons demonstrate that any differences in their technological characteristics do not raise any new questions of safety or effectiveness. ### 510K Summary of Safety and Effectiveness The UB114 also employs a set of front stabilizer wheels that are placed to the front centerline of the drive wheels. The stabilizer wheels aid the user if they encounter a situation that may create an unsafe situation and help keep the Powered Wheelchair from tipping forwards or to the front left or front right sides. The front stabilizer wheels and support arms also aid in the protection for the user's feet and legs. All electrical components (motor gearbox combinations, batteries, battery charger, and internal wring) are housed/enclosed within a solid aluminum alloy Unibody frame. The body support system contains contoured adjustable seating with a full 180degree tilt back for the user. A puff-bladder style or cam-lock style lumbar support is standard for all seating in the UB114. The joystick controller attached to the seating system with a combination length adjustment and tilt angle plate system. This allows the user to totally custom fit the angle and length of position for the joystick. {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo features a stylized depiction of an eagle or bird with three wing-like shapes extending upwards. The bird is positioned above wavy lines, possibly representing water or movement. Encircling the bird is text that reads 'DEPARTMENT OF HEALTH & HUMAN SERVICES - USA'. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 DEC 1 8 2003 Rivertrail Mobility c/o Entela, Inc. N. E. Devinc 3033 Madison Avenue, SF Grand Rapids, Michigan 49548 Re: K033827 Trade/Device Name: UB 114 Regulation Number: 890.3860 Regulation Name: Wheckchair, powered Regulatory Class: II Product Codes: ITI Dated: December 10, 2003 Received: December 10, 2003 Dear: Mr. Devine: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. Ilsting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {3}------------------------------------------------ Page 2 - Mr. Devine: This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4659. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours, Mark A. Millican Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ 7.2 Indication for Use 510k Number (if known) Device Name: UB114 Indications For Use: The intended function and use is to provide motility to persons limited to a sitting position that have the capability of operating a porvered wheelchair. | Prescription Use (Part 21 CFR 801 SubPart D) | AND/OR | Over-The-Counter Use _X_ (21 CFR 807 Subpart C) | |----------------------------------------------|--------|-------------------------------------------------| |----------------------------------------------|--------|-------------------------------------------------| (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) for Division Sign-Off) Division of General, I torative Neurological. Devices K033827 Number:_________________
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...