IMMEDIATE STABILIZING IMPLANT (ISI)
Device Facts
| Record ID | K033392 |
|---|---|
| Device Name | IMMEDIATE STABILIZING IMPLANT (ISI) |
| Applicant | O Co., Inc. |
| Product Code | DZE · Dental |
| Decision Date | Dec 10, 2003 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 872.3640 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The Immediate Stabilizing Implant (ISI) is a one-piece threaded dental implant with the abutment incorporated into the design for a single stage surgical procedure. The implant is intended to be surgically placed in the bone of the upper or lower jaw arches providing support for prosthetic devices resulting in the restoration of the patient's chewing function. Immediate loading can be obtained if implants are rigidly splinted.
Device Story
The Immediate Stabilizing Implant (ISI) is a one-piece, self-tapping, threaded endosseous dental implant. It features an integrated abutment designed for single-stage surgical placement into the upper or lower jaw bone. The device provides structural support for prosthetic dental restorations, enabling the return of chewing function. It is intended for use by dental professionals in a clinical setting. If implants are rigidly splinted, the device supports immediate loading protocols. The implant is available in various diameters (3.25mm, 4.0mm, 5.0mm) and lengths (8mm to 16mm).
Clinical Evidence
No clinical data provided; substantial equivalence is based on design and material characteristics compared to legally marketed predicate devices.
Technological Characteristics
Material: CP Titanium. Design: One-piece, self-tapping, threaded endosseous screw with roughened surface treatment. Dimensions: 3.25mm, 4.0mm, 5.0mm diameters; 8mm-16mm lengths. Energy source: None (mechanical).
Indications for Use
Indicated for patients requiring dental restoration via endosseous implants in the upper or lower jaw to support prosthetic devices and restore chewing function. Contraindications include conditions where rigid splinting is not possible for immediate loading.
Regulatory Classification
Identification
An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.
Special Controls
*Classification.* (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2) *Classification.* Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use; (ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads; (iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system; (iv) The device must be demonstrated to be biocompatible; (v) Sterility testing must demonstrate the sterility of the device; (vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment; (vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians; (viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and (ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.