← Product Code [FPA](/productcode/FPA) · K033290

# TALON INFUSION SET, MODEL IP XXXX (K033290)

_Icu Medical, Inc. · FPA · Apr 12, 2004 · General Hospital · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K033290

## Device Facts

- **Applicant:** Icu Medical, Inc.
- **Product Code:** [FPA](/productcode/FPA.md)
- **Decision Date:** Apr 12, 2004
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 880.5440
- **Device Class:** Class 2
- **Review Panel:** General Hospital
- **Attributes:** Therapeutic

## Indications for Use

The Talon infusion set is an administration infusion set intended to be used for subcutaneous infusion of medicine solutions, such as insulin, from an external infusion pump.

## Device Story

Talon infusion set facilitates subcutaneous delivery of medication (e.g., insulin) from external infusion pump to patient. Device consists of 26-gauge indwelling catheter, tubing, and female luer connector for reservoir attachment. Insertion performed via introduction cannula. Used in clinical or home settings; operated by patient or healthcare provider. Provides fluid path for continuous medication administration; enables patient-controlled or programmed insulin delivery.

## Clinical Evidence

No clinical data provided; bench testing only.

## Technological Characteristics

Materials: PVC/polyethylene, polyvinyl chloride, polytetrafluorethylene, stainless steel, polycarbonate, polypropylene, and silicone lubricant. 26-gauge indwelling catheter. Luer connector interface. Non-electronic, mechanical infusion set.

## Regulatory Identification

An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container.

## Special Controls

*Classification.* Class II (special controls). The special control for pharmacy compounding systems within this classification is the FDA guidance document entitled “Class II Special Controls Guidance Document: Pharmacy Compounding Systems; Final Guidance for Industry and FDA Reviewers.” Pharmacy compounding systems classified within the intravascular administration set are exempt from the premarket notification procedures in subpart E of this part and subject to the limitations in § 880.9.

## Predicate Devices

- Glucopro Infusion Set

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

K033290

ICU Medical, Inc.

APR 1 2 2004

## SUMMARY OF SAFETY AND EFFECTIVENESS Talon Infusion Set

\$807.92(a)(1)

Contact Person

Date of Summary Preparation:

Dale Fairchild Regulatory Manager October 10,2003

\$807.92(a)(2)

Trade Name:

Common Name:

Classification Name:

Talon

Infusion Set

Intravascular administration set (21 CFR 880.5440

§807.92(a)(3)

Legally Marketed Substantially Equivalent Device: Glucopro Infusion Set

\$807.92(a)(4)

Description of Device:

The Talon infusion sets are connected to a medication reservoir proximally (i.e., a syringe that is placed within an infusion pump, such as an insulin pump) and distally inserted into the subcutaneous tissue of the user. The infusion set attaches to the medication reservoir by means of a female luer connector and is inserted into the patient through an introduction

{1}------------------------------------------------

## ICU Medical, Inc.

cannula. The 26 gauge indwelling catheter is connected to tubing of various lengths. The materials used for the components include: PVC/polyethylene; polyvinyl chloride; polytetrafluorethylene; stainless steel; polycarbonate; polypropylene; and, trace amounts of silicone as a lubricant. All of these materials are typically used in medical devices.

8807.92(a)(5)

Intended Use:

The Talon infusion set is an administration infusion set intended to be used for subcutaneous infusion of medicine solutions, such as insulin, from an external infusion pump.

8807.92(a)(6)

Comparison of Technical Characteristics:

The Talon infusion set is similar to legally marketed devices with the same intended use and design.

{2}------------------------------------------------

DEPARTMENT OF HEALTH & HUMAN SERVICES

Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" arranged around the perimeter. Inside the circle is a stylized design featuring three abstract shapes that resemble human figures or waves, stacked on top of each other.

Public Health Service

APR 1 2 2004

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

Mr. Dale Fairchild Regulatory Affairs Manager ICU Medical, Incorporated 951 Calle Amanecer San Clemente, California 92673

Re: K033290

Trade/Device Name: Talon Insulin Pump Infusion Set Regulation Number: 21 CFR 880.5440 Regulation Name: Intravascular Administration Set Regulatory Class: II Product Code: FPA Dated: February 4, 2004 Received: February 5, 2004

Dear Mr. Fairchild:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting vour device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{3}------------------------------------------------

## Page 2 - Mr. Fairchild

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to procced to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4618. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html

Sincerely yours.

fthuch

for

Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

## Indications for Use

510(k) Number (if known): K033290

Device Name: Talon Infusion Set

Indications For Use: The Talon insulin pump infusion set is an administration infusion set intended to be used for subcutaneous infusion of medicine solutions, such as insulin, from an external infusion pump

1 Prescription Use (Part 21 CFR 801 Subpart D)

AND/OR

Over-The-Counter Use (21 CFR 807 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Shere Raneau for ADW 4/8/04

(Division Sign-Off) Division of Anesthesiology, General Hospital. Infection Control, Dental Devices

510(k) Number: K033290

---

**Source:** [https://fda-staging.innolitics.com/device/K033290](https://fda-staging.innolitics.com/device/K033290)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com