K021245 · The Gotzen Group, Inc. · EHD · May 3, 2002 · Dental
Device Facts
Record ID
K021245
Device Name
DEGOTZEN SYNCHRO
Applicant
The Gotzen Group, Inc.
Product Code
EHD · Dental
Decision Date
May 3, 2002
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.1800
Device Class
Class 2
Attributes
3rd-Party Reviewed
Indications for Use
The de Gotzen "synchro" Intraoral Dental X-Ray System is an Extraoral Source X-Ray System, intended to be used for dental radiographic examinations and diagnosis of the teeth, jaw, and oral structures.
Device Story
The de Gotzen synchro is an extraoral dental X-ray system used in clinical settings by dental professionals. It consists of an X-ray tubehead, yoke, articulating arm, wall mount, and an electronic control timer. The system generates X-rays at a fixed 70kVp and 8mA. Operators select exposure times (0.08 to 3.2 seconds) via the control timer switchpads. The device uses 8" or 12" collimating cones to direct the X-ray beam toward the patient's oral region for intraoral imaging. The output is an X-ray beam used to capture dental radiographs, which the clinician interprets to diagnose conditions of the teeth, jaw, and oral structures. The system is designed to be compatible with both film and digital imaging receptors.
Clinical Evidence
Bench testing only. No clinical data provided. Substantial equivalence is based on technical performance comparisons, including tube voltage, current, focal spot size, and leakage radiation measurements.
Technological Characteristics
Extraoral dental X-ray system; 70kVp fixed voltage; 8mA fixed current; 0.7 x 0.7mm focal spot; 8"/12" collimating cones; >2.0mm Al filtration; AC generator; electronic timer with 17-step exposure selection (0.08-3.2s); wall-mounted articulating arm; compatible with film and digital receptors.
Indications for Use
Indicated for dental radiographic examinations and diagnosis of teeth, jaw, and oral structures in patients requiring intraoral imaging.
Regulatory Classification
Identification
An extraoral source x-ray system is an AC-powered device that produces x-rays and is intended for dental radiographic examination and diagnosis of diseases of the teeth, jaw, and oral structures. The x-ray source (a tube) is located outside the mouth. This generic type of device may include patient and equipment supports and component parts.
{0}------------------------------------------------
MAY 0-3 2002
<021245
Page 1 of 4
## 510K Summary Statement for the de Gotzen "synchro" Intraoral Dental X-Ray System.
### General Information
| Manufacturer: | de Gotzen S.r.l<br>Via Roma 45<br>21057 OLIGIATE OLONA (Varese) Italy |
|-----------------------------|-----------------------------------------------------------------------------------------------------------------|
| Establishment Registration: | |
| Telephone: | (011) 39 0331 376760 |
| Fax Line: | (011) 39 0331 376763 |
| Contact Person: | Antonella GASPARRI, International Compliance Office |
| Submitter: | The Gotzen Group, Inc., (dba) TG Group, Inc. Canada<br>3505 Laird Road, Unit #7<br>Mississauga, Ontario L5L 5Y7 |
| Establishment Registration: | #9615032 & Health Canada Establishment: # 692 |
| Telephone: | (877) 557-4888 (Watts Line) |
| Fax Line: | (905) 820-3215 |
| Contact Person: | Wayne Lebeau, President |
| USA Office: | TG Group USA, LLC<br>30 Alden Terrace<br>Flanders, NJ 07836 |
| Telephone: | (973) 927-3730 |
| Fax Line: | (973) 927-4006 |
| Contact Person: | Donald R. Hill, VP Sales & Marketing<br>USA FDA Liaison |
| Summary Preparation Date: | January 24, 2002 |
## Name and Classification
Device Name:
de Gotzen synchro Intraoral Dental X-Ray System 90EHD - Unit, X-Ray, Extraoral with Timer Dental
## Primary Classification Name: Classification Panel:
#### Predicate Devices
The de Gotzen synchro Intraoral Dental x-ray System is substantially equivalent to the following previously cleared and currently marketed devices.
Aztech 70 Gendex Gx770 Sirona Heliodent Vario Dent-x image X-70 Plus Belmont Belray 096
{1}------------------------------------------------
#### Product Description
Page 2 of 4
The de Gotzen synchro Intraoral Dental X-Ray System is comprised of the following main components:
- X-Ray tubehead and yoke .
- . Articulating arm
- Horizontal arm, standard length ●
- Wall Mount
- Electronic control timer (which may be mounted remotely) .
- 8" and 12" Collimating cones .
Optional components:
- . Horizontal arm, short length
- Horizontal arm, long length .
- . Rectangular collimating cone
The power supply (Timer) is regulated to provide a fixed 70kVp, and the x-ray target current is fixed at 8ma. Predefined exposure times may be selected directly through the control timer switchpads. The range of exposure time is 0.08 through 3.2 seconds
#### Intended Use:
The de Gotzen synchro Intraoral Dental X-Ray System is an Extraoral source of x-rays for Intraoral images in dental radiography.
#### Comparison of Technological Characteristics:
Rationale for Substantial Equivalence.
The de Gotzen synchro Intraoral Dental X-Ray System shares the same indications for use, similar materials, design, operational, and functional features and therefore is Substantially Equivalent to the predicate devices listed in this summary.
Table comparing performance of de Gotzen synchro with predicate devices:
{2}------------------------------------------------
| Specifications | Aztech 70 | Gendex Gx770 | Sirona Heliodent Vario | Dent-x Image x-70 Plus | Belmont Belray 096 | de Gotzen synchro |
|-----------------------------------------------------|-------------------------|--------------------------|--------------------------------------------------------|--------------------------------|-----------------------|-------------------------------------------------------|
| Registration Number | K984524 | K935046 | K000672 | K000551 | K963699 | |
| Line Requirements | 110V-120V 50Hz-<br>60Hz | 110V - 130V 60Hz | 100V/110V/120V, 11A<br>220V/230V/240V, 6A<br>50Hz/60Hz | 110V/220V, 50Hz/60Hz | 108V - 132V 50Hz.60Hz | 220V/230V/240V, 8A<br>110V - 120V 5.5A<br>50hZ - 60hZ |
| Generator Type | AC | AC | AC Single Pulse | AC | AC | AC |
| Tube Voltage | 65 kV | 70 kV | 70 kV | 70 kV | 70 kV | 70 kV |
| Tube Current | 8 mA | 7 mA | 7mA | 8 mA | 10 mA | 8 mA |
| Exposure Time Selection | 0.03 -3.0 Sec | 3-99 impulses (28 Steps) | 0.03 - 3.2 Sec | 0.08- 3.2 Sec | 0.02 -3.0 Sec | 0.08- 3.2 Sec. 17 Steps |
| Focal Spot | 0.7 | 0.6mm | 0.8mm | 0.7 X 0.7 mm | 0.8 X 0.8mm | 0.7 X 0.7mm |
| Focal Length | 8in/12in | 8in/12in | 8in/12in | 8in/12in | 8in/12in | 8in/12in |
| Total Filtration in X-ray tube unit | Unknown | Unknown | >2 mm Al | >2.5 mm Al | >2.1 mm Al | >2.0 mm Al |
| | | | | 28 mR/hr at 1m from focal spot | | Less than 2.5 mGy/h |
| Leakage Radiation Compatiabel with Film and Digital | Yes | Yes | Yes | Yes | Yes | Yes |
:
Page 3 of 4
{3}------------------------------------------------
### Conclusion
Page 4 of 4
The deGotzen synchro Intraoral Dental X-Ray System was found to be /is substantially Equivalent to the predicate devices; the Aztech 70, Gendex Gx770, Siron Heliodent Vario, Dent-x image x-70, and Belmont Belray 096. The de Gotzen synchro shares the same indications for use, similar materials, design, operational, and functional features as the current marketed predicate devices. It has been shown to be safe and effective when used as labeled.
{4}------------------------------------------------
#### DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/4/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the top. Inside the circle is a stylized image of an eagle.
#### Public Health Service
**MAY 03 2002**
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
The Gotzen Group, Inc. % Mr. Robert Mosenkis President CITECH 5200 Butler Pike PLYMOUTH MEETING PA 19462-1298
Re: K021245 Trade/Device Name: deGotzen synchro Intraoral X-Ray System Regulation Number: 21 CFR 872.1800 Regulation Name: Extraoral source x-ray system Regulatory Class: II Product Code: 90 EHD Dated: April 18, 2002 Received: April 19, 2002
Dear Mr. Mosenkis:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (sections 531-542 of the Act); 21 CFR 1000-1050.
{5}------------------------------------------------
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. .
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at one of the following numbers, based on the regulation number at the top of this letter:
| 8xx.1xxx | (301) 594-4591 |
|----------------------------------|----------------|
| 876.2xxx, 3xxx, 4xxx, 5xxx | (301) 594-4616 |
| 884.2xxx, 3xxx, 4xxx, 5xxx, 6xxx | (301) 594-4616 |
| 892.2xxx, 3xxx, 4xxx, 5xxx | (301) 594-4654 |
| Other | (301) 594-4692 |
Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html.
Sincerely yours,
Nancy C. Brogdon
Nancy C. Brogdon Director, Division of Reproductive, Abdominal, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{6}------------------------------------------------
Image /page/6/Picture/0 description: The image shows the logo for a group. The logo consists of a large letter 'G' with the word 'Group' written to the right of it. The letter 'G' is stylized and appears to be partially obscured by a dark shape.
# XI. INDICATIONS FOR USE STATEMENT
Applicant: de Gotzen S.r.L.
510(k) Number (if known): k_02/245
Device Name: de Gotzen "synchro" Intraoral Dental X-Ray System
Indications for Use: The de Gotzen "synchro" Intraoral Dental X-Ray System is an Extraoral Source X-Ray System, intended to be used for dental radiographic examinations and diagnosis of the teeth, jaw, and oral structures.
(Please do not write below this line – Continue on another page if needed)
Concurrence of CDRH, Office of Device Evaluation (ODE)
| Prescription Use | <span style="text-decoration: underline;">✓</span> | OR | Over-The-Counter Use | <span style="text-decoration: underline;">_____</span> |
|----------------------|----------------------------------------------------|----|----------------------|--------------------------------------------------------|
| (Per 21 CFR 801.109) | | | | |

| (Division Sign-Off) | |
|--------------------------------------|---------|
| Division of Reproductive, Abdominal, | |
| and Radiological Devices | |
| 510(k) Number | K021245 |
| (Division Sign-Off) |
|------------------------------------------|
| Division of Reproductive, Abdominal, ENT |
| And Radiological Devices |
510K Number___________________________________________________________________________________________________________________________________________________________________
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.