STERN MICRO ERA ATTACHMENT SYSTEM
Device Facts
| Record ID | K020391 |
|---|---|
| Device Name | STERN MICRO ERA ATTACHMENT SYSTEM |
| Applicant | Sterngold |
| Product Code | DZE · Dental |
| Decision Date | Mar 8, 2002 |
| Decision | SESE |
| Submission Type | Special |
| Regulation | 21 CFR 872.3640 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The Stern Micro ERA System is a resilient retention device for dental prosthesis, designed to be used in restoration of removable dentures.
Device Story
The Stern Micro ERA Attachment System is a dental prosthetic component used to provide retention for removable dentures. The system consists of nylon male attachments available in six color-coded sizes (white, orange, blue, gray, yellow, red) representing increasing levels of retention, a resin female component, and associated stainless steel and titanium alloy instruments. A black processing male is provided as a fabrication tool to incorporate the final snap-in male into the dental appliance. The device is used by dental professionals in a clinical setting to facilitate the restoration of removable dentures, offering a smaller profile than previous systems to allow for additional space while maintaining functionality and aesthetics.
Clinical Evidence
Bench testing only.
Technological Characteristics
System includes nylon male attachments, resin female components, and stainless steel and titanium alloy instruments. The device is a mechanical retention system for dental prostheses. No software or electronic components.
Indications for Use
Indicated for use as a resilient retention device for dental prosthesis in the restoration of removable dentures.
Regulatory Classification
Identification
An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.
Special Controls
*Classification.* (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2) *Classification.* Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use; (ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads; (iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system; (iv) The device must be demonstrated to be biocompatible; (v) Sterility testing must demonstrate the sterility of the device; (vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment; (vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians; (viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and (ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.
Predicate Devices
- Stern ERA System (K913348)