← Product Code [HWC](/productcode/HWC) · K020159

# SMITH & NEPHEW TWINFIX TI QUICK T (K020159)

_Smith & Nephew, Inc. · HWC · Mar 26, 2002 · Orthopedic · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K020159

## Device Facts

- **Applicant:** Smith & Nephew, Inc.
- **Product Code:** [HWC](/productcode/HWC.md)
- **Decision Date:** Mar 26, 2002
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 888.3040
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic

## Indications for Use

The Smith & Nephew TwinFix Ti Quick T is indicated for use as a suture anchor to facilitate percutaneous or endoscopic soft tissue procedures. The Smith & Nephew Suture Anchor is indicated for shoulder, foot, ankle, elbow, knee, wrist and hand. Examples of such procedures include: Shoulder: Bankart lesion repairs, SLAP lesion repairs, acromio-clavicular separation repairs, rotator cuff repairs, capsular shift or capsulolabral reconstructions, biceps tendonesis, and deltoid repairs. Foot and Ankle: Hallux Valgus repairs, medial or lateral instability repairs/reconstructions, achilles tendon repairs/reconstructions, midfoot reconstructions, and metatarsal ligament/tendon repairs/reconstructions. Elbow, Wrist and Hand: Scapholunate ligament reconstructions, ulner or radial collateral ligament reconstructions, tennis elbow repair, and biceps tendon reattachment. Knee: Extra-capsular repairs: medial collateral ligament, lateral ligament, and posterior oblique ligament. Iliotibial band tendonesis, and patellar realignment and tendon repairs, including vastus medialis obliquous advancement.

## Device Story

Sterile, single-use suture anchor system; designed to anchor nonabsorbable polyester suture to bone; facilitates reattachment of soft tissues during percutaneous or endoscopic orthopedic procedures. Used by surgeons in clinical/OR settings. Device provides mechanical fixation of soft tissue to bone, enabling healing of ligaments and tendons. Benefits include minimally invasive surgical access and secure tissue-to-bone attachment.

## Clinical Evidence

No clinical data provided; substantial equivalence based on design and technological characteristics.

## Technological Characteristics

Sterile, single-use titanium suture anchor; nonabsorbable polyester suture; mechanical fixation principle; intended for orthopedic soft tissue repair.

## Regulatory Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

## Predicate Devices

- Acufex T-Fix Rotator Cuff Guide System ([K941364](/device/K941364.md))
- PEBA Anchor/Suture Combination ([K972326](/device/K972326.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

K02015-9

page 1 of 2

## 510(k) Summary

Smith & Nephew TwinFix Ti Quick T

MAR 2 6 2002

Date Prepared:

January 7, 2002

This 510(k) summary is being submitted in accordance with the requirements of SMDA 1990 and 21 CFR §807.92.

Submitter A.

Smith & Nephew, Inc. Endoscopy Division 160 Dascomb Road Andover, MA 01810

### B. Company Contact

William McCallum Regulatory Affairs Specialist

#### C. Device Name

Trade Name: Smith & Nephew TwinFix Ti Quick T

Common Name: Suture Anchor Suture, Nonabsorbable, Polyester

Classification Name: Screw, Fixation, Bone

#### D. Predicate Devices

Acufex T-Fix Rotator Cuff Guide System, K941364 PEBA Anchor/Suture Combination K972326

### E. Description of Device

The Smith & Nephew TwinFix Ti Quick T is a sterile single use anchor system which is designed to anchor suture to bone for the reattachment of soft tissues.

{1}------------------------------------------------

Page 2 of 2

# F. Indications For Use

The Smith & Nephew TwinFix Ti Quick T is indicated for use as a suture anchor to facilitate percutaneous or endoscopic soft tissue procedures. The Smith & Nephew Suture Anchor is indicated for shoulder, foot, ankle, elbow, knee, wrist and hand. Examples of such procedures include: Shoulder:

Bankart lesion repairs, SLAP lesion repairs, acromio-clavicular separation repairs, rotator cuff repairs, capsular shift or capsulolabral reconstructions, biceps tendonesis, and deltoid repairs. Foot and Ankle:

Hallux Valgus repairs, medial or lateral instability repairs/reconstructions, achilles tendon repairs/reconstructions, midfoot reconstructions, and metatarsal ligament/tendon repairs/reconstructions. Elbow, Wrist and Hand:

Scapholunate ligament reconstructions, ulner or radial collateral ligament reconstructions, tennis elbow repair, and biceps tendon reattachment.

Knee:

Extra-capsular repairs: medial collateral ligament, lateral ligament, and posterior oblique ligament. Iliotibial band tendonesis, and patellar realignment and tendon repairs, including vastus medialis obliquous advancement.

### G. Comparison of Technological Characteristics

The Smith & Nephew TwinFix Ti Quick T is substantially equivalent in design, function, and intended use to the following predicate devices:

Acufex T-Fix Rotator Cuff Guide System, K941364 (May 16, 1994). T-Bar

PEBA Anchor/Suture Combination, K972326 (June 23, 1997). Anchor and Suture

W. Shin. M. Calhoun

William McCallum Regulatory Affairs Specialist

{2}------------------------------------------------

Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" around the perimeter. Inside the circle is an abstract symbol that resembles three human profiles facing right, with flowing lines beneath them.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

MAR 2 6 2002

Mr. William McCallum Regulatory Affairs Specialist Smith & Nephew, Inc Endoscopy Division 160 Dascomb Road Andover, Massachusetts 01810

Re: K020159

Trade/Device Name: Smith & Nephew TwinFix Ti quick T Regulation Number: 888.3040 Regulation Name: Screw, Fixation, Bone Regulatory Class: II Product Code: HWC Dated: January 16, 2002 Received: January 17, 2002

Dear Mr. McCallum:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

{3}------------------------------------------------

## Page 2 - Mr. William McCallum

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, «Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html

Sincerely yours,

R. Mark N. Millbern, Ph.D.

elia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

# KO)O S 510(k) Number :

Device Name: Smith & Nephew TwinFix Ti Quick T

Indications for Use:

The Smith & Nephew TwinFix Ti Quick T is indicated for use as a suture anchor to facilitate percutaneous or endoscopic soft tissue procedures. The Smith & Nephew Suture Anchor is indicated for shoulder, foot, ankle, elbow, knee, wrist and hand. Examples of such procedures include:

Shoulder:

Bankart lesion repairs, SLAP lesion repairs, acromio-clavicular separation repairs, rotator cuff repairs, capsular shift or capsulolabral reconstructions, biceps tendonesis, and deltoid repairs. Foot and Ankle:

Hallux Valgus repairs, medial or lateral instability repairs/reconstructions, achilles tendon repairs/reconstructions, midfoot reconstructions, and metatarsal ligament/tendon repairs/reconstructions.

Elbow, Wrist and Hand:

Scapholunate ligament reconstructions, ulner or radial collateral ligament reconstructions, tennis elbow repair, and biceps tendon reattachment.

Knee:

Extra-capsular repairs: medial collateral ligament, lateral ligament, and posterior oblique ligament. Iliotibial band tendonesis, and patellar realignment and tendon repairs, including vastus medialis obliquous advancement.

(PLEASE DO WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Prescription Use her (Per 21 CFR 801.109)

OR

(Optional Format 1-2-96)

Over-the-Counter No

Mark N Mulkerson
(Division Sign-Off)

General, Restorative and Neurological Devices

025

51 % ) Numb

---

**Source:** [https://fda-staging.innolitics.com/device/K020159](https://fda-staging.innolitics.com/device/K020159)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
