PORTA GEO TI MODEL #2004

K012834 · Wieland Edelmetalle GmbH & Co. · EJT · Nov 1, 2001 · Dental

Device Facts

Record IDK012834
Device NamePORTA GEO TI MODEL #2004
ApplicantWieland Edelmetalle GmbH & Co.
Product CodeEJT · Dental
Decision DateNov 1, 2001
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.3060
Device ClassClass 2

Indications for Use

Porta Geo Ti is a gold-platinum ceramic alloy that can be used by dental technicians to fabricate dental appliances for patients. It is intended for manufacturing Inlays/ Onlays Partial crowns Crowns Short span bridges Long span bridges Removable partials and can be used for Telescopic and milling work. Porta Geo Ti can be veneered with suitable dental ceramics as well as with dentalcomposites.

Device Story

Porta Geo Ti is an extra-hard gold-platinum ceramic alloy (95.4% noble metal content) used by dental technicians in a laboratory setting to fabricate dental restorations. The alloy is copper-free, facilitating telescopic and milling applications. Technicians cast or machine the alloy into the desired dental appliance shape, which may then be veneered with dental ceramics or composites to achieve aesthetic results. The device serves as the structural framework for dental prosthetics, providing corrosion resistance and biocompatibility. It benefits patients by providing a durable, aesthetically pleasing, and biocompatible material for restorative dental work.

Clinical Evidence

Bench testing only. The device complies with international standard ISO 9693 for dental ceramic-fused-to-metal restorations. No clinical data provided.

Technological Characteristics

Extra-hard gold-platinum ceramic alloy; 95.4% noble metal content; copper-free. Complies with ISO 9693. Form factor: dental casting alloy. No energy source or software components.

Indications for Use

Indicated for patients requiring dental restorations including inlays, onlays, partial crowns, crowns, short/long span bridges, and removable partials. Suitable for telescopic and milling work. No specific contraindications listed.

Regulatory Classification

Identification

A noble metal alloy is a device composed primarily of noble metals, such as gold, palladium, platinum, or silver, that is intended for use in the fabrication of cast or porcelain-fused-to-metal crown and bridge restorations.

Special Controls

*Classification.* Class II (special controls). The special control for these devices is FDA's “Class II Special Controls Guidance Document: Dental Noble Metal Alloys.” The devices are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 872.9. See § 872.1(e) for availability of guidance information.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K012834 #### Premarket Notification 510(k) Porta Geo Ti NOV 0 1 2001 ### 5. 510 (k) Summary | Submitter of 510(k): | Wieland Edelmetalle GmbH & Co. | |----------------------|--------------------------------| | | Schwenninger Str. 13 | | | D-75179 Pforzheim | | | Germany | | | Phone: +49-7231-3705-0 | | Contact person: | Dr. Gerhard Polzer | |-----------------|----------------------------------| | Phone: | +49-7231-3705-219 | | Fax: | +49-7231-357959 | | e-mail: | gerhard.polzer@wieland-dental.de | 2001-07-21 Date of Summary: Porta Geo Ti Trade name: Classification name: Product code: C.D.R section: Classification: :w Alloy, gold based, for clinical use EJT 872.3060 Class II Legally marketed equivalent device: 510(k) number: Argedent 77PF K 935507 #### Device description Porta Geo Ti is an extra-hard gold-platinum ceramic alloy with a high content of noble metals (95,4%), intended for dental technicians to fabricate dental restorations. lt has an indication which ranges from inlays/onlays and crowns up to long span bridges with two or more pontics and removable partials. It is free of copper and therefore suitable for telescopic and milling work. Porta Geo Ti is highly corrosion resistant and has an excellent biocompatibility. It fully complies to the international standard ISO 9693 and fulfills the essential requirements of the European directive 93/42/ECC concerning medical devices. Porta Geo Ti can be veneered with suitable dental ceramics and with dental composites, in which the golden yellow color of the alloy provides an excellent basis for manufacturing aesthetically pleasing dental restorations. {1}------------------------------------------------ Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 NOV 0 1 2001 Dr. Gerhard Polzer Director of Regulatory Affairs Weiland Edelmetalle GmbH & Company Schwenninger Strabe 13 D-75179 Pforzheim, GERMANY Re: K012834 Trade/Device Name: Porta Geo Ti, Model #2004 Regulation Number: 872.3060 Regulation Name:Alloy, Gold Based, For Clinical Use Regulatory Class: II Product Code: EJT Dated: October 18, 2001 Received: October 22, 2001 Dear Dr. Polzer: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not {2}------------------------------------------------ ### Page 2 - Dr. Polzer mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours. Timothy A Ulatowski Director Division of Dental, Infection Control and General Hospital Devices Office of Device Evaluation Center for Devices and Radiological Health {3}------------------------------------------------ K012834 # rket Notification 510(k) Porta Geo Ti ## 4. Statement of indication for use Porta Geo Ti is a gold-platinum ceramic alloy that can be used by dental technicians to fabricate dental appliances for patients. It is intended for manufacturing - Inlays/ Onlays ● - Partial crowns . - . Crowns - Short span bridges . - Long span bridges . - . Removable partials and can be used for - Telescopic and milling work . Porta Geo Ti can be veneered with suitable dental ceramics as well as with dentalcomposites. Susan Dunne (Division Sign-Off) Pivision of Dental, Infection Control, .. General Hospital D For Branber ------------------------------------------------------------------------------------------------------------------------------------------------------------------
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...