K012823 · Ness-Neuromuscular Electrical Stimulation Systems · GZI · Nov 14, 2001 · Neurology
Device Facts
Record ID
K012823
Device Name
MODIFICATION TO HANDMASTER
Applicant
Ness-Neuromuscular Electrical Stimulation Systems
Product Code
GZI · Neurology
Decision Date
Nov 14, 2001
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 882.5810
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Handmaster is intended to be used for the following indications: Maintenance or increase of range of motion, reduction of muscle spasm, prevention or retardation of disuse atrophy, muscle reeducation, and increasing local blood circulation. In patients suffering from upper limb paralysis due to C5 spinal cord injury or hemiplegia due to stroke, it is also intended to provide hand active range of motion and hand function.
Device Story
Handmaster is a portable, one-channel functional neuromuscular stimulator for personal use. System consists of a control unit and a splint housing five surface electrodes. Splint, constructed of fiber-reinforced plastic with polyurethane cushions, holds wrist at 20° extension and positions electrodes on hand/forearm. Electrodes are metal foil coated with carbon-impregnated polymer, using water-soaked cloth pads as conductive interface. Device delivers constant-voltage symmetrical biphasic Russian waveform stimulation. Microprocessor-controlled switching activates muscles in combinations (cyclic or continuous) for finger/thumb extension and flexion. User selects programs via mode button; intensity adjusted via +/- buttons (10 levels). Clinician-accessible panel allows adjustment of maximum current and global timing factor. Powered by rechargeable Ni-Cd batteries. Used by patients for home-based therapy to improve hand function and range of motion; clinician sets initial parameters.
Clinical Evidence
Clinical data provided to support the expanded indication for hemiplegic patients. No specific study metrics (e.g., p-values, CIs) reported in the summary; evidence demonstrates safe and effective use for the expanded indication.
Technological Characteristics
Portable one-channel neuromuscular stimulator. Constant-voltage symmetrical biphasic Russian waveform. Fiber-reinforced plastic splint with polyurethane cushions. Electrodes: metal foil with carbon-impregnated polymer and water-soaked cloth pads. Rechargeable Ni-Cd batteries. Microprocessor-controlled stimulation switching and intensity adjustment. Seven-segment display for intensity levels.
Indications for Use
Indicated for patients with upper limb paralysis due to C5 spinal cord injury or hemiplegia due to stroke requiring maintenance/increase of range of motion, reduction of muscle spasm, prevention/retardation of disuse atrophy, muscle reeducation, increased local blood circulation, and restoration of hand function.
Regulatory Classification
Identification
An external functional neuromuscular stimulator is an electrical stimulator that uses external electrodes for stimulating muscles in the leg and ankle of partially paralyzed patients (e.g., after stroke) to provide flexion of the foot and thus improve the patient's gait.
DanMed, Inc. AM800 Automove Electrical Muscle Stimulator (K972997)
Submission Summary (Full Text)
{0}------------------------------------------------
## 510(K) SUMMARY
## N.E.S.S. NEUROMUSCULAR ELECTRICAL STIMULATION SYSTEMS LTD. HANDMASTER 12823
N.E.S.S. Neuromuscular Electrical Stimulation Systems Ltd. Applicant: 19 Ha-Haroshet Street Keidar Center Suite 207 P.O. Box 2500 Industrial Zone Ra'anana, 43465 ISRAEL Tel: 011-972-9-7485738 Fax: 011-972-9-7485740
## Contact Persons:
Jonathan S. Kahan, Esq. Hogan & Hartson, L.L.P. Columbia Square 555 Thirteenth Street, NW Washington, DC 20004-1109 Tel: (202) 637-5794 Fax: (202) 637-5910
Handmaster Trade Name:
Common/Usual Name: External Functional Neuromuscular Stimulator
External Powered Muscle Stimulator and Classification Name: Functional Neuromuscular Stimulator
## Predicate Devices
Systems Neuromuscular Electrical Stimulation N.E.S.S. Handmaster (K952273, K982482, and K010837); DanMed, Inc. AM800 Automove Electrical Muscle Stimulator (K972997).
{1}------------------------------------------------
Image /page/1/Picture/0 description: The image shows a handwritten sequence of numbers and letters. The sequence starts with "K012823" on the top line. Below this, there is a second line that reads "20F=3". The handwriting is somewhat rough, but the characters are generally legible.
## Intended Use
The Handmaster is intended to be used for the following indications: Maintenance or increase of range of motion, reduction of muscle spasm, prevention or retardation of disuse atrophy, muscle reeducation, and increasing local blood circulation. In patients suffering from upper limb paralysis due to C5 spinal cord injury or hemiplegia due to stroke, it is also intended to provide hand active range of motion and hand function.
## Device Description
one-channel electrical a portable, is The Handmaster neuromuscular stimulator for personal use. The stimulator serves five surface electrodes held on to the upper limb by a splint. The control unit housing the stimulator may be worn using the shoulder strap provided, or it may be placed on any stable surface. The splint is worn on the hand and forearm. The splint is connected to the control unit by a light cable.
A single channel of constant-voltage symmetrical biphasic Russian waveform stimulation is delivered to the muscles through five surface electrodes. Microprocessor-controlled switching of the stimulation between these five electrodes allows the muscles to be activated in combinations either cyclically or continuously. The stimulation is ramped up at the beginning and down at the end of each cycle.
The electrode locations allow the Handmaster to give finger and thumb extension and flexion. The user can select from five stimulation programs by pressing the mode button on the control unit. The active mode is displayed by a light glowing next to the labeled mode. When the device is stimulating, the light flashes. The stimulation programs are They comprise either cyclic or supplied as microprocessor firmware. continuous activation of the finger and thumb extensors and flexors.
The user can increase or decrease the stimulation intensity in ten discrete levels by pressing on buttons labeled "+" or "-" on the control unit. The intensity is This alters the duration of the stimulation pulse. displayed as a number (0 to 9) on a seven-segment display.
During the initial system set-up, the clinician opens a clinical panel within the control unit. Adjustments are provided for limiting the maximum current to the extensor muscles and to the flexor muscles, along
{2}------------------------------------------------
with a global timing factor which increases or decreases the duration of the with a giobal villing offectively speeding or slowing the cyclic hand motion.
The user starts or stops the stimulation program by pressing a If required, the user may also stop all stimulation "trigger" button. immediately by switching OFF the device.
The Handmaster splint is used to hold the wrist joint at a comfortable extension angle (20°), and also to hold the electrodes on the comfortable oncerce and hand segments. It is constructed from fiber-reinforced plastic with soft polyurethane cushion sections to distribute stress over bony with bols poly arounded are made from metal foil coated with carbonimpregnated polymer. Replaceable water-soaked cloth pads are arranged over the electrodes to provide a conductive interface with the skin. A over and crood bottle is provided to facilitate wetting of the electrode pads.
Rechargeable nickel-cadmium batteries power the device. Battery status can be displayed both during device operation and while recharging butteries. Both visual and audio battery-low warnings are provided. It is necessary to disconnect splint/electrodes in order to recharge the batteries, as the same socket is used for both.
## Performance Data & Substantial Equivalence
The Handmaster subject of this submission is exactly the same device in all aspects to the market-cleared Handmaster. The only difference between the devices is the expansion of the indication to include the ability of the Handmaster to provide hemiplegic patients with active range of motion and hand function. This expansion is supported by clinical data that demonstrates that the Handmaster can be safely and effectively used for this indication, like for the other device indications, without presenting any unreasonable risk of illness or injury. Therefore, the Company believes that substantial equivalence has been demonstrated without raising any new safety and/or effectiveness issue.
{3}------------------------------------------------
Image /page/3/Picture/2 description: The image shows a logo with two distinct elements. On the left, there is a circular seal with text around the perimeter, likely the name of an organization. To the right of the seal, there is a stylized graphic consisting of three curved lines stacked vertically, resembling a bird in flight or a flowing ribbon. The logo appears to be a symbol representing a department or agency, possibly related to health or government services.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
NOV 1 4 2001
Jonathan S. Kahan, Esq. Hogan & Hartson, L.L.P. Representing N.E.S.S., Ltd. Columbia Square 555 Thirteenth Street, NW Washington, DC 20004-1109
Re: K012823
Trade/Device Name: Handmaster Regulation Numbers: 21 CFR 890.5850 and 21 CFR 882.5810 Regulation Names: Powered Muscle Stimulator and External Functional Neuromuscular Stimulator Regulatory Class: Class II Product Codes: IPF and GZI Dated: August 16, 2001 Received: August 16, 2001
Dear Mr. Kahan:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration
{4}------------------------------------------------
Page 2 - Jonathan S. Kahan, Esq.
and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours.
Sincerely yours,
R. Muli n-Millen
Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative, and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
NOV 1 4 2001
## INDICATIONS FOR USE STATEMENT
# 510(k) Number:_K 0/2823
Device Name:
Handmaster
## Indications for Use:
The Handmaster is intended to be used for the following indications: Maintenance or increase of range of motion, reduction of muscle spasm, prevention or retardation of disuse atrophy, muscle reeducation, and increasing local blood circulation. In patients suffering from upper limb paralysis due to C5 spinal cord injury or hemiplegia due to stroke, it is also intended to provide hand active range of motion and hand function.
#### (PLEASE DO NOT WRITE BELOW THIS LINE -CONTINUE ON ANOTHER PAGE IF NEEDED)
510(k) Number K012823
**Prescription Use**
(Per 21 CFR 801.109)
ຂອງເຂົາ ໄຂວາງບຸດໄວພາອັກ ນັກສ of Alabola of Creacanti, Restorative 100-60 3 2010. -
OR
7-7
Over the Counter Use
510(x) Number
Mark N. Melkerson
vision of General. Restorative and Neurological Devices
510(k) Number -
K012823
11/DC - 64270/1 - #1379228 v1
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.